Home / Shop / Product Types / Air Heaters / Sureheat Max Air Heater & Max Ht Air Heater
- Description
- Specifications
The 076189 Tutco SureHeat Max HT Air Heater is designed for 30000 watts of power, 380 voltage three phase, and a maximum amperage of 45.6 amps. Call Jobco Inc. for quantity pricing or special pricing at 479-424-1300.
The Tutco SureHeat MAX-HT provides a compact, efficient heater for heating air or inert gases to 1652°F (900°C).
A dual probe type “K” thermocouple with a convenient terminal block is included for ease of wiring. Each probe of thermocouple is used to measure exit air temperature. One is typically used for process temperature control and the other to monitor high temperature limit. When powered and controlled with Tutco approved controls (sold separately) you are provided a convenient, cost effective solution for safely controlling the AC power to your Tutco SureHeat MAX-HT. If operated correctly, the heater will operate continuously for 5000 hours or longer.
Specifications
Maximum Inlet Air Pressure 60 PSI (4 BAR)
Maximum Inlet Air Temperature 200°F (93°C)
Maximum Exit Air Temperature 1652°F (900°C)
Minimum Airflow (Recommended) 18 SCFM (510 SLPM)
Exit Air Connection: 1-1/2" FNPT
Inlet Air Connection: 1-1/4" FNPT
Safety Approvals: CE
Control/Limit Sensors: Dual Probe Type “K” isolated, ungrounded, exposed junction TC
(both used to measure exit temperature)
General Information
Environmental Conditions:
Ambient Temperature 32°F to 104°F (0°C to 40°C)
Humidity 0% to 95% R.H.
Ventilation:
Use in a well-ventilated area away from excess dust, dirt, and moisture.
Cleaning:
With unit OFF and unplugged, exterior surfaces may be wiped clean using a dry, lint-free cloth.
Protective Earthing:
Each heater comes with a convenient grounding stud and hardware located at the inlet of the heater for
protective means of earthing.
Dimensions/Mounting
NOTE: The inlet side of the heater is located where the leads/power feedthrus come out of the housing.
Failure to install the heater in its proper orientation can result in heater damage and is not covered under the
manufacturer’s warranty.

Precautions
1. Use filtered air. Avoid grease, oil, or oil vapors, corrosive or reactive gases which will damage heater.
Note: When using compressed air a pressure reduction valve and an oil & water separation unit should be
installed to avoid contaminating the heater and reduce heater life.
2. Operate at safe voltages as shown on the Performance Curves (see page 9). Excess voltage will cause
premature failure.
3. If using a process air temperature thermocouple other then one of the supplied “K” thermocouple probes it is
highly recommended that one of the exit thermocouples be used with a temperature limiting board to protect
against over temperature protection (OSRAM SYLVANIA Part #F076359 – set to 1680°F (915°C)).
4. If using closed-loop control, use a temperature controller with a fast sampling period (<500ms) and minimal
overshoot.
WARNING: Avoid Damage to Housing--DO NOT OVER-TIGHTEN!
3/8” NPT (Sensor): 4 ft-lb
3/4” NPT (Power): 25 ft-lb
1-1/4” NPT (Air): 7 ft-lb
(Excessive force will crack housing and void warranty)
Sylvania SureHeat MAX-HT Operating Manual - Click Here for the SureHeat Max Air HT Heater Operating Manual
SHOCK HAZARD!
Only qualified individuals should install this heater and related controls.
Follow all applicable electrical codes and use proper wiring.
BURN/FIRE/EXPLOSION HAZARD!
Do not use in hazardous environments, and/or near explosive or reactive gases, or
combustible materials. Avoid contact with the heater or exit accessories during or soon
after operation. DO NOT USE NEAR VOLATILE OR COMBUSTIBLE MATERIALS.
Limited Warranty
OSRAM SYLVANIA warrants that all products to be delivered hereunder will be free from defects in material and
workmanship at the time of delivery. OSRAM SYLVANIA's obligation under this warranty shall be limited to (at
its option) repairing, replacing, or granting a credit at the prices invoiced at the time of shipment for any of said
products. This warranty shall not apply to any such products which shall have been repaired or altered, except
by OSRAM SYLVANIA, or which shall have been subjected. OSRAM SYLVANIA shall be liable under this
warranty only if (A) OSRAM SYLVANIA receives notice of the alleged defect within sixty (60) days after the date
of shipment; (B) the adjustment procedure hereinafter provided is followed, and (C) such products are, to
OSRAM SYLVANIA’s satisfaction, determined to be defective.
THE WARRANTY SET FORTH IN THE PRECEDING PARAGRAPH IS EXCLUSIVE AND IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR OF MERCHANTABILITY.
The information contained in this manual is based on data considered to be true and accurate. Reasonable
precautions for accuracy has been taken in the preparation of this manual, however OSRAM SYLVANIA
assumes no responsibility for any omissions or errors, nor assumes any liability for damages that may result
from the use of the product in accordance with the information contained in this manual.
Please direct all warranty/repair requests or inquiries to the place of purchase, and provide the following
information, in writing:
(A) Order number under which products were shipped
(B) Model/Serial Number of product
(C) Reason for rejection
PRODUCTS CAN NOT BE RETURNED TO OSRAM SYLVANIA WITHOUT AUTHORIZATION.
Replacement, repair, or credit for products found to be defective will be made by the place of purchase. All
products found to be not defective will be returned to the Buyer; transportation charges collect or stored at
Buyers expense.